FEMU based estimation of composite action between floating topping and full-scale CLT floors

Rezime

A floating concrete topping has been a common solution to improve durability, fire protection, acoustics and more recently vibration performance of cross-laminated timber (CLT) floors. In structural analysis, such a topping is normally modelled as an additional dead load, assuming no composite action with the CLT panels. However, rare vibration tests on small-scale specimens demonstrated that some degree of the composite action undoubtedly exists. This study combines numerical and experimental methods to identify its actual levels in two full-scale floors. Their FE models were developed based on the full-layerwise plate theory of Reddy, with improved kinematics to account for the interlayer slip at the CLT-topping interface. The slip moduli were calibrated through a 3-step FE model updating designed to align the numerical and experimentally identified natural frequencies. The effective flexural stiffness of the actual composite floors was estimated based on two distinct methods: (i) back-calculation from the measured fundamental frequency using the standard natural frequency equation, and (ii) the Gamma method outlined in Eurocode 5. Both methods yielded approximately 85% higher values than the baseline numerical models without the composite action. Moreover, the corresponding coupling factors of approximately 31% significantly exceed the 5–15% range recommended in the recent U.S. Mass Timber Floor Vibration Design Guide.